-12%

LG HS18ISY ( 2.0 HP Split Type Aircon - Standard Inverter ThinkQ )

50,755.00
List price: 57,888.00
Short description:

Free installation for the first 10 ft. copper tubing including bracket and breaker.
(Applicable to Stock on Hand Only)
Promo duration: July 1 - September 30, 2022.

10 days
HS18ISY
5 item(s)
+
Specifications
  • 70% Energy Saving
  • Dual Inverter Compressor
  • Active Energy Control
  • Auto Cleaning
  • Auto Operation(AI)
  • Allergy Filter
  • Dry (Dehumidification) Operation
  • Jet Cool
  • Sleep Mode
  • Comfort Air
  • Smart Diagnosis
  • LG ThinQ
  • Gold Fin Copper Condenser
  • Parts: 10 Year Compressor
  • Labor: 1 Year Parts & Service
  • 998 * 345 * 210 mm (W*H*D) indoor
  • 770 * 545 * 288 mm (W*H*D) outdoor
  • 11.2 kg (Indoor)
  • 30.7 kg (Outdoor)
  • 13.2 kg (Indoor)
  • 32.8 kg (Outdoor)
  • 998 x 345 x 210 mm / 39.29 x 13.58 x 8.26 inches (In)
  • 770 x 545 x 288 mm / 30.31 x 21.45 x 11.33 inches (Out)
  •  1,068 x 425 x 279 mm / 42.04 x 16.73 x 10.98 (inches) (In)
  • 920 x 588 x 393 mm / 36.22 x 23.14 x 15.47 (inches) (Out)
  • Optional: Area must be surveyed first, to figure out which size unit (HP) of the air conditioner is best suited to your area. 

*Additional fees to charge for mobilization fee.

Installation Policies & Guidelines

 Installation package is inclusive of : Standard Installation Works

  1. Free survey ( for the 1st visit ) within 20 km. radius.
  2. Installation of copper tube & rubber insulation from indoor to outdoor unit for the first 10 ft.
  3. Electrical wiring connection for indoor and outdoor unit only.
  4. Drilling of hole on CHB walls up to 8 inches thick ( for refrigerant pipe to pass thru )
  5. Installation of drain pipe one ( 1 ) meter.
  6. Labor ( 1 ) day only.
  7. P1,500 + CDU / outdoor bracket up to 6 ft. high and breaker with weather proof enclosure.

Exclusions: ( charge to customer )

OTHERS: Additional fees to charge ( determine from actual assessment ) excluded from above standard installation works.

  1. In excess of 10 ft. on unit piping, insulation, electrical and other consumable materials for the installation P300.00/ft.
  2. Civil, carpentry and / or masonry works.
  3. Government permit and mechanical plans.
  4. Exhaust deflectors.
  5. Layout of elect. feeder lines ( electrical source to CB )
  6. Clipping works for embedded pipes.
  7. Weather proof / cladding pipes.
  8. Service platform 6 ft. and above. Safety issue requiring to install service area for servicing of unit.